WT-1011RC IP65 GSM Remote Controller
And Alarm S
y
stem
WT-1011RC IP65 – USER MANUAL – Rev.1.6 – Technical Support: [email protected]
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
*RETR#22222000
Example of Returned Message:
#RETR=22222000
This function allows the second relay to latch at a specific time (GOTX) later after the
first relay has latched and when the first relay has switched off the second relay will
switch off after a specific time (GOTY).
Text Command to Enable this Function:
*FTRY#2
Text Command to Enable the normal Function (5.3.1):
*FTRY#1
Example:
To program the device so that when you latched relay 1, relay 2 will latch 5 seconds
(GOTX) later.
*GOTX#00005
Example of Returned Message:
#GOTX=00005
Example:
To program the device so that when the relay 1 closes, relay 2 will closes
10 seconds (GOTY) later.
*GOTY#00010
Example of Returned Message:
#GOTY=00010
Note: When using this function, the *GOTX# delay time value you programmed must be
smaller than the latching time of output relay 1 (*GOT1#) otherwise the system will return an
error message.